Answer: (1) Fault phenomenon. The safety valve fails to open automatically.

(2) Cause analysis.

1) The spring adjustment pressure of the spring-type safety valve is too large and should be readjusted;

2) The sealing surface is contaminated by the medium or crystallized to cause adhesion or rust;

3) The gap between the valve stem and the bushing is too small;

4) The spring is permanently deformed.

(3) Elimination method.

1) Readjust the safety valve;

2) Blow or grind the sealing surface, and perform a manual exhaust test to eliminate the problem;

3) Appropriately increase the gap between the valve stem and the bushing;

4) Replace the spring.