6-7 Briefly describe the treatment method for long-term shutdown of screw air compressors.
Danh mục

6-7 Briefly describe the treatment method for long-term shutdown of screw air compressors.

For long-term shutdown of screw air compressors, drain condensates, fix faults, seal openings, wrap with oil paper, replace lubricating oil, and drain cooling water based on shutdown duration.
Chi tiết vụ án

Answer: 
(1) Shutdown for more than 3 weeks:

   1) Drain the condensate in the oil cooler and aftercooler;

   2) If there is any fault, it should be eliminated first for future use;

   3) Drain the condensate in the oil drum, oil cooler, and aftercooler.


(2) Shutdown for more than 2 months (in addition to the above procedures, the following treatment is required):

   1) Seal all openings to prevent moisture from entering;

   2) Wrap the safety valve and control panel with oil paper to prevent rust;

   3) Replace the lubricating oil before shutdown and run for 30 minutes. After two days, drain the condensate in the oil drum and cooler;

   4) Drain all cooling water.