Answer: (1) Fault phenomenon. When the air compressor starts, the running indicator light does not light up and the motor does not start.
(2) Cause analysis.
1) Fuse burns out;
2) Protection relay operates;
3) Start relay fails;
4) Start button has poor contact;
5) Voltage is too low;
6) Motor failure;
7) Machine body failure;
8) Phase loss protection relay operates;
9) The air compressor fails to reset after a minor or major fault alarm.
(3) Elimination method.
1) Replace with a new fuse;
2) Check and calibrate the relay;
3) Check and repair the start button after checking that the power supply is normal;
4) Check and restore the power supply;
5) Repair and eliminate the motor fault;
6) Check the cause of the machine body fault and eliminate it;
7) Check the power supply and motor phase sequence;
8) Reset the alarm signal.