10-14 Explain the reasons why the operating current of the screw air compressor is lower than the normal value, and how to deal with it?
Danh mục

10-14 Explain the reasons why the operating current of the screw air compressor is lower than the normal value, and how to deal with it?

Explores reasons for low operating current in screw air compressors, such as air filter blockage, and provides solutions.
Chi tiết vụ án

Answer: (1) Cause analysis.

1) The air consumption is too large, and the air compressor is running in the low pressure range;

2) The air filter is blocked;

3) The air inlet valve is not working properly;

4) The capacity adjustment valve is not adjusted properly.

(2) Elimination method.

1) Check the consumption and add a compressor if necessary;

2) Check or replace;

3) Disassemble, clean and add lubricating grease;

4) Reset and adjust.